• TI玻璃管标签RI-TRP-DR2B-40

    日期:2023-03-24 浏览:507

    Device Overview

    1、Features

    • Best-in-Class Performance Through Patented Half-Duplex (HDX) Technology

    • MPT 1360-Bit Type

    • ISO 11784 and ISO 11785 Compliant

    • Patented Transponder Tuning Provides Stable and High Read and Write Performance

    • Insensitive to Almost All Nonmetallic Materials



    2、Applications

    • Access Control

    • Asset Management

    • Vehicle Identification

    • Waste Management

    • Container Tracking



    3、Description

    TI玻璃管标签RI-TRP-DR2B-40.jpg

    TI 32-mm glass transponders provide superior performance and operate at a resonance frequency of 134.2 kHz. Specific products are compliant to ISO 11784 and ISO 11785 global open standards. TI LF transponders are manufactured with TI's patented tuning process to provide consistent read and write performance. Before delivery, the transponders undergo complete functional and parametric testing to provide the high quality that customers have come to expect from TI. The transponder is well suited for use in a broad range of applications including, but not limited to, access control, vehicle identification, container tracking, asset management, and waste management applications.


    Device Information

    PART NUMBER 

    PACKAGE (PIN)

    BODY SIZE

    RI-TRP-DR2B-40

    TGB (0) 

    3.85 mm × 32.2 mm


    Specifications

    1、Absolute Maximum Ratings

    over operating free-air temperature range (unless otherwise noted)


    MIN

    MAX

    UNIT

    TA       Operating temperature

    -25

    80

               Write (program) temperature

    0

    70

    TSTG    Storage temperature

    -40

    125(1)

    (1)For a total of 1000 hours


    2、ESD Ratings

    Device is fully encapsulated and protected. No ESD classification applies.


    3、Recommended Operating Conditions

    over operating free-air temperature range (unless otherwise noted)


    MIN

    MAX

    UNIT

    Tr       Recommended operating temperature

    0

    70


    4、Electrical Characteristics

    over operating free-air temperature range (unless otherwise noted)

    PARAMETER

    RI-TRP-DR2B

    UNIT

    Functionality

    MPT


    Memory

    1360 

    bits

    17 R/W

    pages

    Operating Frequency

    134.2

    kHz

    Modulation

    FSK (frequency shift keying), 134.2 kHz and 123.2 kHz


    Transmission Principle

    HDX (half duplex)


    Power Source

    Powered from the reader signal (batteryless)


    Typical Read Range

    ≤100 (1) 

    cm

    Typical Programming Range

    30% of specified reading range


    Typical Read Time

    86

    ms

    Typical Programming Time

    293

    ms

    Typical Programming Cycles

    100000


    (1) Depends on RF regulation in country of use, the reader antenna configuration used, and the environmental conditions.


    Physical Characteristics

    over operating free-air temperature range (unless otherwise noted)

    PARAMETER

    RI-TRP-DR2B

    UNIT

    Case Material 

    Glass


    Protection Class 

    Hermetically sealed


    EMC

    Programmed code is not affected by normal electromagnetic interference or x-rays


    Signal Penetration

    Transponder can be read through almost all nonmetallic material


    Dimensions

    ⌀3.85 ±0.05 × 32.2 ±0.6

    mm

    Weight

    0.85

    g